Fault codes "Hotpoint Ariston"

If you see an error code on the screen, try restarting the device. To do this, unplug it from the network for 15-20 minutes. After switching on, look at the scoreboard. If the icons are highlighted again, look for the decoding in the instructions or in our table.

Fault code Description How to fix
F01 Problems in the operation of the motor start relay.
  1. Check the part. Use a multimeter, also visually inspect for burn marks.
  2. Replace relay if defective.
F02 Start relay open (does not start). Perhaps there was an overload in the network, a sharp power surge. Diagnostics and installation of a new element.
F03 Incorrect operation of the control module. To inspect, remove the board from the installation site. It is advisable to entrust the diagnosis to the master. He will ring the contacts and elements of the module, repair or replace.
F04 The fan in the freezer is not working. Causes:
  • Frozen ice.
  • Wiring failure.
  • The fan motor burned out as a result of power surges.
  • The grease in the motor bearings has dried up.
What can be done:
  • If ice builds up on the blades, defrost the chamber.
  • Inspect wiring for damage. Replace the cable if integrity is compromised.
  • Install a new fan motor.
  • Renew bearing grease.
F05 Broken control valve. Checking and replacing the element.
F06 The element that controls the operation of the defrost heater is not functioning. It is better to contact the master for verification and further replacement.
F07 The integrity of the wiring of the defrost heating element is broken. We need to inspect all parts of the wiring, replace burnt parts.
F08 Motor solenoid valve broken. Your actions:
  • Breakdown diagnostics.
  • Possible repair or replacement of a part.
F09 Problems with EEPROM. Violation of the firmware of the board. You need to check and flash the module.
F10 Model dependent:
  • Technique with NO-FROST - problems with the damper.
  • Units with CCZ - changeover valve problems.
Call a specialist for diagnosis.
F11 The fan control has failed. Install the correct item.
F12 The connections between the electronic board and the screen are broken. Check contacts. You may need to tighten connections.
F13 The fan in the refrigerator is not working. The reasons are similar to error F10. Only the repair of the part will help.
F14 The control module is not functioning correctly. Inspect and install a new part.
F15 The thyristor that controls the heater has failed in the Mutiflow system. Inspection, search for solutions to fix the problem.
F16 The fan blades in the refrigerator compartment are not working. In Nou Frost models - a malfunction of the heater control element.
F17 Problems with the electronic valve (Aqua Care, F18). Pump problems (Ever Fresh).
F20 The light in the refrigerator does not turn on. Install a new light bulb.
F21 The NTC sensor is broken. It will help to change the non-working element.
F22, F23 NTC does not work in the refrigerator or in the evaporator.
F24, F25 Breakdown of NTC in the freezer or in its evaporator.
F26 NTC does not function in the CCZ system.
F28 Problems with the screen control board. Specialist diagnostics, repair.

The following are errors that indicate problems with the keys on the control panel.

A1 and A2 breakdowns in Hotpoint Ariston refrigerators

Breakdown code A1 means that the temperature in the compartments exceeds the norm.

Likely causes:

  • The fan is overgrown with ice and does not work. Cold air does not enter the compartment.
  • The evaporator freezes. His sensor is broken.
  • The heater burned out.
  • The main board is not working properly.

What you can do yourself:

  • Check the tightness of the door to the body. Perhaps the hinges have sagged or the seal has worn out. Then warm air enters the chamber and the temperature rises. Replacing the seal is easy with your own hands. Try tightening the door fasteners or replacing the hinges.
  • The refrigerator is off because there is no electricity. Reboot the system and turn on the equipment again.

If you have recently loaded food into the chamber, wait 20-30 minutes for the temperature to recover.

  • Defrost the equipment until the build-up of ice and snow has come off the walls.

If these methods do not help, it is better to consult a specialist.

Error A02 indicates an overtemperature in the freezer compartment. The steps are the same as in the previous case. Additionally, you can check the thermostat, whether the correct values ​​\u200b\u200bare set.

Now you know what to do if the code is displayed on the screen. Do not delay with the check so that the breakdown does not become fatal.

Every home has a refrigerator, without which it is impossible to store food for a long time. Today, those who wish to purchase this household appliance have an extensive choice. The quality of food and the health of family members depend on the performance of the refrigerator. Reviews of already determined consumers will help you choose the right model.

Brand Ariston

A good option would be Ariston units belonging to the middle segment. Since 1975, they have been produced by Merloni Elettrodomestici, which has branches in the Russian Federation. Its founder was Vittorio Merloni.

Consumers note in the units of this brand:

  1. acceptable cost;
  2. capacity;
  3. optimal dimensions;
  4. no need for regular defrosting (with No Frost technology);
  5. excellent design;
  6. automatic maintenance of the required temperature regime;
  7. long service life;
  8. reliability;
  9. quality;
  10. additional functions.

Ariston technology over the years of its existence has proven itself from the best side. Evidence of this is the popularity of the brand among the population.

Exploitation

Refrigerators Hotpoint Ariston perform functions through electronic control. Temperature control and No Frost options, switching operating modes freezer impossible without an electronic unit.

When a problem occurs, a code appears on the display specifying the location of the problem. This makes the troubleshooting process easier. Models, the cost of which is more democratic, have indicators that reflect possible problems. Their appearance provokes a corresponding light signal, on the basis of which they conclude that it is necessary to carry out repair work.

The indicator, like the code, identifies the area where the damage occurred, but does not specify the cause. A similar set of functions ensures long-term operation of the household appliance.

Model overview Hotpoint Ariston RMBA.1185.1F

This is a two-chamber household appliance in which the freezer is located at the bottom. Refrigerator Hotpoint Ariston RMBA.1185.1F has one compressor, two doors, controlled by an electromechanical system.

The Hotpoint Ariston RMBA.1185.1F model is equipped with:

  1. No Frost option;
  2. the possibility of super-freezing;
  3. freshness zone.

Errors in the operation of the Ariston refrigerator

TO frequent malfunctions include:

  1. noise, knocking or rattling that occurs during the operation of the unit;
  2. the appearance of too much ice;
  3. shutdown of a household appliance that occurs immediately after putting it into operation

The cause of this problem may be in the relay (starting, protective), compressor or winding that has failed. In the latter case, the machine is constantly knocked out, as the wires overheat. If the compressor is to blame, then the root cause is a breakdown of the sensor responsible for the temperature. It, in turn, is damaged due to insufficient interaction with the motor of the household appliance, insufficient temperature for the refrigerator compartment

This problem can be caused by a blockage formed in the capillary pipeline. It entails violations in the movement of the refrigerant, as well as:

  1. the formation of smudges;
  2. lack of response to turning off the light;
  3. freezing of ice on the walls of the refrigerator (example in the photo).

IN this case the reason is not following the rules of operation. New generation Ariston refrigerators are defrosted once every six months. If the unit is equipped with the No Frost function, then such a problem is the result of problems with the thermostat.

If you have problems with Hotpoint Ariston refrigerators, you must contact the service center specialists. They will repair the failed parts without damaging other important parts of the appliance, which cannot be guaranteed when trying to fix the refrigerator yourself.

Breakdown factors

The main cause of breakdowns in the unit is the negligence shown by the consumer during operation. If he did not read the instructions attached to the refrigerator, he is able to make serious shortcomings in its maintenance and use.

Most often, malfunctions occur due to:

  1. opening the unit for a long time;
  2. loose pressing of the door;
  3. placing finished products in the refrigerator that have not reached the required temperature;
  4. lack of regular defrosting prescribed by the instruction manual.

Fault codes

Like other modern refrigerators, Ariston units have a clear list of fault codes, through which it takes a minimum of time to identify and eliminate the problem that has arisen.

Each code reflects violations that occur in a particular segment of the household appliance.

Among them are errors in (on):

  1. compressor (F01, F02);
  2. power nodes (F03);
  3. fan (F04, F11, F13);
  4. heating element (F06, F07);
  5. valve with electromagnetic drive (F08);
  6. software (F09);
  7. damper (F10, F05);
  8. electronic unit (F14);
  9. control and indication boards (F28, F12);
  10. source of consecration (F20);
  11. touch screen (F40);
  12. thyristor (F15).

The list of errors for Hotpoint Ariston refrigerator models may vary depending on the available options and design features.

Errors A1 and A2 in the Ariston unit

A separate group includes faults displayed on the display under the codes A1 and A2. They appear when the temperature regime is violated.

Dangerous overtemperature (A1) leads to the establishment of 0 degrees Celsius in order for the consumer to use the products for their intended purpose in the next day. Problems in the software, the heating element or the temperature sensor can cause such a reaction of the refrigeration unit. To identify and eliminate them, you should call a specialist.

If the problem that has arisen has not been resolved within the allotted time period, then the code A2 is already displayed on the display. In this situation, it is necessary to repair the unit and check the quality of the products stored in it. It is likely that they will be damaged.

The reason for the temperature increase in the refrigerator compartment can be:

  1. failure of the compressor motor;
  2. damage to the sensor responsible for the temperature regime;
  3. malfunctions in the control system;
  4. problems with the heater in the evaporator;
  5. freon leak.

As a result, the unit will consume more electricity, while generating insufficient cooling temperature.

Debugg

What needs to be done to solve the problem:

  1. Read the instruction manual.
  2. Restart home appliance.

To do this, turn off the refrigerator from the network and set both temperature controllers to the zero position. After we turn on the unit and set the required temperature.

  1. turn on the refrigerator (as in paragraph 1), first removing the terminals from the solenoid valve;
  2. set the mode "both cameras together";
  3. watch the temperature rise.

If no changes are observed, then the triac and (or) the microcontroller port are most likely damaged. In the latter case, the item is not recoverable. Self-elimination of a malfunction, even if according to the instructions, entails a refusal to repair the Hotpoint Ariston refrigerator under warranty.

Modern refrigerators equipped with a display greatly simplify maintenance in case of technical problems that require immediate resolution. To do this, manufacturers have createdAriston refrigerator error codes and in the event of a breakdown of one or another node, the smart household unit will tell the user how to properly and effectively fix the problem without spending a lot of time on it. Also, refrigerator errorsAristonhelp the specialist necessary information about problem areas and failures in electronic components. If you have noticed a specific code and are looking for information about it, then take a look at the table below. We have collected and deciphered everything for youmistakes refrigerator hotpoint ariston

Code Description of the fault Solutions
F01 The start-up relay of the motor-compressor is malfunctioning Diagnostics of this component is required, followed by replacement if necessary
F02 Motor-compressor start relay open Diagnose the relay and replace if necessary
F03 Notifies you of power board failures or failures Call the board, measure the values, replace with a new one if necessary
F04 Freezer cooling fan not turning Fan motor repair or complete replacement
F05 Electronic damper defect
F06 There was a malfunction of the thyristor control of the defrost heating element Detailed diagnostics, failure detection and replacement. Expert help required
F07 Defrost heating element open circuit

ringing electrical circuit.Replacement of the burned-out section of the wire

F08 Solenoid valve defective Finding the cause and replacing the component
F09 The malfunction affected the firmware meeting program (EEPROM) Electronics testing. Firmware, replacement
F10 If the refrigerator isno- Frost: Indicates damper failure On/Off. If the refrigerator isCCZ: indicates a breakdown of the secondary solenoid valve Requires professional diagnostics and qualified assistance
F11 A defect or breakdown of the thyristor for controlling the refrigeration fan is detected Detailed diagnostics with subsequent replacement of the faulty unit
F12 Control board and LCD board not communicated Communication required between boards
F13 Refrigerator fan stopped working Diagnostics, replacement of a faulty fan or its repair
F14 Power board defect Calling, finding the cause and replacing
F15 The problem with the thyristor control of the heating element of the Mutiflow system
F16 The fan in the refrigerator compartment does not work. If the refrigerator isno- Frost: problem with the heating element of the Mutiflow system Only professional inspection and repair
F17 For refrigerators with Ever Fresh: the vacuum pump is defective. For Aqua Care refrigerators: defective solenoid valve Only professional inspection and repair
F18 Aqua Care solenoid valve failed Component diagnostics and replacement
F20 Refrigerator light does not work Self-replacing the lamp or calling the master
F21 NTC Sensor replacement
F22 Malfunction of the electronic sensorNTCin the refrigerator compartment Sensor replacement
F23 The temperature sensor in the refrigerator compartment is out of orderNTC evaporator Sensor replacement
F24 NTC Sensor replacement
F25 The temperature sensor in the freezer has failed.NTC evaporator Sensor replacement
F26 Problems with the sensorNTC air CCZ Sensor replacement
F28 Breakdown of the electronic display board of the refrigerator Board diagnostics, ringing, replacement
F40 ON/OFF key display is broken
F41 The "I Sage" key does not respond to pressing Replace key, check contacts
F42 Function control button «holiday" out of order Replace key, check contacts
F4 3 Ice Party button is out of order Replace key, check contacts
F44 The "Ever Fresh" button is out of order Replace key, check contacts

F45

"Super Freeze" button is out of order Replace key, check contacts
F46 "Super Cool" button is out of order Replace key, check contacts
F47 The "Alarm Message" button is out of order Replace key, check contacts
F49 Button "F" rigo+” out of order Replace key, check contacts
F50 Button " frigo-" out of order Replace key, check contacts
F51 Kopka " CCZ» temperature control out of order Replace key, check contacts
F52 freezer+” out of order Replace key, check contacts
F53 Freezer compartment temperature control button “freezer-" out of order Replace key, check contacts
Code Description of the fault Solutions

Modern household appliances are equipped with special systems that allow you to produce operational diagnostics performance. Refrigerator error codes report a malfunction of individual blocks and assemblies, electrical circuits and sensors. Timely repairs will extend the life of the equipment, restore functionality and prevent more complex problems from occurring.

How the diagnostic system works and general definitions

Software-electronic integrated solutions are used to monitor the state of equipment. The sensor readings are sent to the data processing unit. In case of deviation from the normal parameters, an alert signal is given. Individual positions are checked continuously. For others - only when you start the diagnostic program.
If it is displayed, for example, e2 Siemens refrigerator error, it means that the process of measuring the temperature in the freezer is not working properly. As a rule, it is recommended to replace the evaporator sensor. But experienced craftsmen know that the exact localization of the problem is more difficult. Insufficient compressor performance can also disrupt the freezing mode set by the manufacturer.

Errors on refrigerators are recorded using direct and indirect methods. The fact of breaking the electrical circuit is determined simply. This event can be used to control the complete closing of the refrigerator door by installing the appropriate sensor. If you check the change in temperature, you will be able to register its abnormal increase in the chamber in time. It can be caused by the same reason.

The above examples indicate that only an experienced craftsman can sometimes do the exact localization of problems. But when an error a2, or another, appears on the information board of the refrigerator, any user will be able to draw certain conclusions if they know the decoding of the codes. In modern household appliances This type controls the following parameters:

    The temperature outside, inside the refrigerator and freezer, individual boxes and ice-makers.

    Operability of fans, compressor, mechanical components of ice makers, heating element of the defrosting system, valves.

    Mains voltage.

    Closing the freezer/refrigerator compartment.

    The functional state of the adjusting keys and buttons, internal wiring, sensors, indication and control unit.

It should be noted that refrigerator error a2(different code) can have a different meaning. Be sure to take into account the features of a particular model of equipment and the manufacturer's recommendations for troubleshooting and troubleshooting technologies.

Codes and their decoding

Let's take a closer look at a few popular brands and standard means fault alerts. First, here are the error codes for Atlant refrigerators:

    F1, F2, F3- malfunction of the sensors of the refrigerating chamber, evaporator, freezer compartment, respectively.

    Code F4 means that the voltage level in the power supply has become below the norm, which is determined by the manufacturer at 170 V. In the refrigerator Atlant error f5 reports an unacceptable increase in voltage above 255V. These malfunctions do not apply to equipment breakdowns. But it must be understood that going beyond the boundaries of the established range leads to premature wear of individual parts, reduced productivity, and emergency situations. The user himself can check the real voltage in the network using measuring instruments. Next, it will be necessary to take measures to stabilize it and repair the refrigerator.

    Atlant F6 (F7) refrigerator errors- malfunctions of the compressor of the refrigerating (freezing) chamber. They can occur during a power outage, power surges in the network, connecting welding machines and other powerful consumers.

    Letter "H" ("L") warns that the temperature in one of the chambers is too high (low). Measurement of the corresponding indications is carried out in a continuous mode, therefore, it is necessary to treat the appearance of signals with understanding. If a lot of food is loaded into the camera, the letter " H". When is reached normal temperature, it will turn off. Similarly, temporarily, the notation appears "L"after the fast freeze cycle has been activated. However, if these letters flash for several hours, there is a problem.

Ariston refrigerator errors are checked for a larger number of positions. In this technique, the fault detection system is more complex. But one must take into account the presence different systems damage indication. This must be taken into account when conducting diagnostic work. In one model refrigerator Ariston error a1 indicates an excessive rise in temperature in the fridge/freezer compartment.

Better equipped equipment will allow you to determine the location of the breakdown:

    Code F22 indicates a malfunction of the NTC temperature sensor in the refrigerator compartment.

    If displayedF23, the specialist will understand that a similar defect is in the control device of the evaporator.

    F24 (F25) will report a breakdown of the sensor in the freezer (the evaporator of the corresponding compartment).

Here are other codes and decodings that will help determine more precisely in the refrigerator Hotpoint Aristonmistakes, failures and malfunctions:

    F01- a defect in the relay that controls the operation of the compressor.

    F02– the same electronic component is open, the compressor is not powered.

    F03- a malfunction in the board that controls the power units of the refrigerator.

    F04– the fan in the freezer compartment does not rotate.

    F05- malfunction of the damper.

    F06- the thyristor supplying voltage to the heating element is damaged.

    F07- break in the power supply circuit of the heating element.

    F08– Malfunctions in the valve with an electromagnetic drive.

    F09- Software failure.

    Code F10– has different meanings in the following models:

    • NO-FROST series - damper is damaged;
    • series with CCZ - valve defect with solenoid valve (secondary circuit).

    F11- the thyristor supplying voltage to the fan (refrigeration compartment) is damaged.

    F12- broken contacts, open circuit between the display and control units.

    F13– no fan rotation (in the refrigerator compartment).

    F14- a defect in the electronics unit that controls the power units of the refrigerator.

    F15– the thyristor supplying voltage to the heating element is damaged (in refrigerators equipped with Multifiow).

    Code F17 has different meanings in the following models:

    • breakdown of the vacuum pump for the EverFresh series;
    • solenoid operated valve failure for AquaCare series.

    F20- The light source in the refrigerator compartment has burned out.

    F28– the board of the display unit is faulty.

    F40- on touch screen The on/off button is broken.

    F41; 42; 43; 44; 45; 46; 47; 49; 50; 51; 52; 53– the keys do not function: ICage; holiday; IceParty; EverFresh; superfreeze; supercool; "Accident"; FRIGO - more; FRIGO - less; CCZ; FREEZER - more; FREEZER - less.

Accurate diagnosis with a large number of codes is easier to make. So, in the refrigerator HotpointAriston error a1 notifies only about the high temperature in the refrigerator / freezer. But the real source of problems can be a faulty sensor, a heater, a software glitch.

Some of the same designations from different manufacturers mean excellent breakdowns. So, if an e2 error appeared in the Gorenie refrigerator, it indicates a malfunction of the evaporator sensor. In the old Bosch model, this indicates an error that can only be corrected by installing a working control unit. But in new refrigerators, the readings of this sensor are not used.

We list the codes used by individual manufacturers:

For Burning refrigerators, errors are determined by the following indication:

    Code E2 reports a malfunction in the refrigeration compartment;

    E4- freezer performance problems.

Whirlpool Refrigerator Error Codes:

    AL01– defect of the sensor of the refrigerating chamber;

    AL02– incorrect operation of the temperature sensor;

    AL03- the temperature sensor of the freezer is not functioning correctly;

    CF(ComunicatoinFailure, Communication failure) - the absence of a normal electrical connection between the control units and the display device.

Refrigerator Toshiba, so reports the malfunctions that have arisen:

    H1C– the compressor is blocked;

    H3E– the temperature sensor does not work;

    HLL– excess moisture has appeared in the system, or a refrigerant leak occurs;

    H6E- freezer fan blocked

    LG refrigerator errors:

    ER/FS- malfunction of the freezer compartment. Some faults can be corrected after a restart.

    ER/RS- breakdown of the thermostat in the refrigeration division, or a break in its power circuit.

    ER/DS- failure of the sensor, which is included in the automatic defrosting system.

    ER/DH- defrosting occurs according to the wrong algorithm.

    ER/FF– the fan is broken or blocked.

If the indication “0 FF” appears on the display of the LG refrigerator, then this is not evidence of a breakdown. It indicates the included mode "Demo", which is used to demonstrate equipment at exhibitions and in stores.

INDESIT Refrigerator Error Codes

Features of repair operations

From the above information, it is clear that in reality much depends not so much on the indication of individual errors, but on the qualifications of the master performing the repair operations. A good specialist will not only quickly identify a malfunction. He will offer the best way to solve problems with minimal time and money. As an example, we use the error codes of SamsungSidebySide refrigerators with the features of performing repair operations. Indication is carried out using illuminated LED segments. The exact location of them can be found in the official instruction manual. Enter the self-diagnosis mode by pressing the Quick Freeze/Cool keys at the same time. Flashing certain fragments will inform the user about the following Samsung refrigerator errors:

    Error codes for Ariston refrigerators (A2) help to recognize errors in a timely manner or identify errors in operation. Ariston branded equipment is very popular in Russia. Refrigerators of the brand are distinguished not only by their stylish design, excellent technical specifications and a wide range of functions, but also its own self-diagnosis system, which warns the user of possible malfunctions in the functioning of the refrigerator.

    What does error code A2 mean?

    Error codes for the Hotpoint Ariston A2 refrigerator are more like a notification from the self-diagnosis system that the temperature in the refrigerator is too high to properly store food. Therefore, do not immediately sound the alarm. According to the refrigerator manual, this error is deciphered as a non-compliance with the norm for cooling capacity. This happens if for certain time the refrigerator could not reach the desired temperature. To put it simply - A2 indicates that the refrigerator does not cool well.

    There are many reasons for this error in the work. If a refrigerator with No Frost gives an error, this will certainly be taken into account when conducting diagnostics. The main reasons for insufficient cooling are as follows.

    1. Defrost timer. Performs the function of turning on and off the evaporator defrosting from accumulated frost. The formation of a snow coat leads to the retention of cold air - it cannot provide cooling for the chambers. A broken defrost timer is replaced with a new part.
    2. TEN. It is he who is responsible for defrosting the evaporator. This is a special heating element. During operation, it can burn out, and sometimes the contacts simply oxidize or leave. The heating element must be removed and its condition checked.
    3. Shutter between chambers. Performs the function of a thermostat in refrigerators with No Frost. Sometimes it becomes clogged, an obstacle is created for the passage of cold air from one chamber to another.
    4. Fan. Provides cooling to the main compartment by blowing cold air from the evaporator. Breakage of the fan, its blades, fouling with snow and ice lead to the fact that cold air stops flowing. In this case, cooling may be completely absent.
    5. Control module. Controls the operation of the entire refrigerator as a whole, including the diagnostic system. It processes the incoming information and issues commands to the nodes - the fan, the compressor unit, the thermostat, the heating element. If no command is received, then the node does not work either.
    6. capillary pipeline. A very thin tube through which the refrigerant moves. Due to the small internal diameter, blockages, traffic jams often form in it, the movement of freon stops - the cooling capacity is lost or the cooling becomes uneven.
    7. Compressor unit. It can be called the heart of the refrigerator. If it wears out, then the cooling capacity decreases, the cooling efficiency drops.

    These are just some of the problems due to which the A2 symbol may appear on the refrigerator display. Also, do not exclude wear of sealing rubber, freon leakage, operating conditions that do not comply with the instructions. In any case, you should immediately contact the staff of the Gnome Workshop. We know everything about refrigerators, we have a full set of original spare parts and professional tools in stock. You can call our master at any time of the day - he will promptly arrive at the request, make repairs, leave you a full contract for services and a guarantee for spare parts.